Get a Quote

Control Panels & Starters

DOL and star-delta starters, VFD panels, PLC panels, and MCCs — wired, tested, and documented in-house at our Thane facility, with the switchgear, relay cards, and motors to go with them.

Built In-House

The Panel Shop Behind the Gearbox Shop

Every motor we gear needs something to start it. Our panel shop builds that something: DOL starters for small drives, star-delta assemblies to ~25 HP, VFD panels with protection and bypass, PLC panels with the logic configured, and motor control centres for multi-drive installations. Enclosures come in powder-coated mild steel, stainless steel, PVC, or polycarbonate, built to the ingress protection your site needs.

Panels are function-tested before dispatch and ship with as-built drawings and test certificates. And because the same vendor supplies the geared motor and the drive, the overload settings, ramp times, and interlocks arrive already matched to the machine.

Engineering Data

Panel & Starter Types at a Glance

Type Typical Rating Enclosure Options Notes
DOL starter Small motors, 240 / 415 V ABS / polycarbonate / MS Contactor + overload relay; simplest start
Star-delta starter Up to ~25 HP, 415 V 3-phase MS / SS Reduced-current starting for larger motors
VFD panel Sized to drive MS / SS / polycarbonate Drive + protection + cooling + bypass options — see VFD Drives
PLC panel Per I/O count, 380–415 V incomer MS / SS / PVC Logic configured & tested — see PLC Controllers
MCC panel Multi-feeder installations MS, compartmentalised One lineup for pump houses and process bays
Contactors / switchgear ~9 A to 800 A, 22–440 V coils Loose supply or built into panels
Relay interface cards 8-channel, 24 V DC PLC-output isolation and field interfacing
Loose motors Fractional to ~5 HP common Crompton Greaves, Havells, LS; single & three phase

Ratings shown are typical build points, not limits — larger and special panels are engineered case-by-case.

Complete Range

Panels, Starters, Switchgear & Motors We Commonly Arrange

Control panels — MCC, PLC, motor control (7 models)

Fabricated in-house: mild steel, stainless steel, PVC and polycarbonate enclosures.

ModelSupplyNotes
Control panelPLC Control Panels
Control panelMotor Starters / Star-Delta
Control panelPLC Control Panels
Control panelPLC Control Panels
Control panel220-380Electric Motors
Control panelElectric Control Panels; recent addition
Control panelElectric Control Panels; recent addition
VFD panels (2 models)

Drive + bypass + protection built and tested as one panel.

ModelSupplyNotes
VFD control panel
VFD control panel
Motor starters — DOL & star-delta (3 models)

DOL and star-delta assemblies, typically up to ~25 HP at 415 V.

ModelSupplyNotes
Motor starter
Motor starter415 V AC | 380-440V AC
Motor starter240V | 220-240V AC
Switchgear — contactors (1 model)

Contactor ranges approximately 9 A to 800 A, 22–440 V AC coils.

ModelSupplyNotes
Contactor / switchgearrecent addition
Relay cards (1 model)

8-channel 24 V DC relay interface cards.

ModelSupplyNotes
8-channel relay cardLogispark; recent addition
Induction motors — loose supply (8 models)

Crompton Greaves, Havells and LS motors supplied alongside panels and geared drives.

ModelSupplyNotes
Induction motor
Induction motor415 V
Induction motor
Induction motor220 v
Induction motor
Induction motorrecent addition
Induction motorrecent addition
Induction motorrecent addition

Every panel is a custom build — the list above shows common configurations. Share your motor list and duty for an exact proposal.

The Anand Gears Advantage

Why the Panel and the Gearbox Should Come From One Shop

Settings Arrive Matched

Overload relays set to the real motor FLA, ramp times set to the real gearbox and load inertia, interlocks wired to the real machine sequence — not left for site to figure out.

Documents That Match Reality

As-built wiring drawings and function test certificates ship with every panel — the paperwork your electrician actually needs at 2 a.m.

One Call When Something Trips

Mechanical or electrical, it's the same vendor. No gearbox-supplier-blames-panel-vendor loop — we own the whole drive chain.

Industry Solutions

Where These Panels Go to Work

Pump Houses & Water Treatment

MCCs and star-delta banks with level interlocks and pump changeover logic.

Conveyor & Crusher Drives

Sequenced starting across long conveyor trains and crusher duty starters — with the conveyor gearboxes to match.

Sugar, Cement & Process Plants

Heavy-duty starters and MCC lineups for sugar mill and cement plant equipment.

OEM Machine Builders

Machine-mounted panels shipped with the geared motors, ready to bolt on and wire through.

HVAC & Cooling Towers

Fan starter and VFD panels for cooling tower drives, weather-protected builds available.

Panel Replacements

Like-for-like rebuilds of ageing starters with modern protection — documented before the old panel comes off the wall.

Common Questions

Panels & Starters FAQ

Does Anand Gears build custom control panels?

Yes — panel building is done in-house at our Thane facility. DOL and star-delta starters, VFD panels, PLC panels, and motor control centres are wired, inspected, and function-tested before dispatch, and ship with as-built drawings and test certificates.

Up to what rating do you build starters?

DOL starters for small motors, and star-delta assemblies typically up to around 25 HP at 415 V three-phase. Above that, or where soft starting matters, we recommend a soft starter or a VFD panel — often the better choice anyway for mechanical life of the gearbox and driven machine.

What enclosure materials and protection ratings are available?

Mild steel (powder-coated), stainless steel for washdown and corrosive areas, and PVC or polycarbonate for light-duty and non-metallic requirements. Ingress protection is built to the site requirement — dust-protected indoor panels up to gasketed washdown-grade builds. The rating is stated on the panel test certificate.

Which switchgear brands go inside your panels?

Commonly Schneider Electric MCBs, MCCBs, contactors and overload relays, with contactor ranges from roughly 9 A to 800 A depending on duty. Other brands can be used to match a plant standard — tell us your preference when enquiring.

Do you also supply loose motors?

Yes. Crompton Greaves, Havells and LS induction motors — single-phase and three-phase, foot or flange mounted — are supplied loose or paired with our gearboxes as complete geared drives with the starter or VFD panel to run them.

Is Anand Gears an authorised distributor of the switchgear and motor brands?

No. Anand Gears is an independent supplier and panel-builder, not an OEM or authorised distributor of any of the brands listed. Brand and model names are the property of their respective owners. Final model availability, lead-time and price are confirmed at the time of quotation, and specifications should be cross-checked against the manufacturer's official datasheet before ordering.

Brand and model names on this page are the property of their respective owners. Anand Gears is an independent supplier and panel-builder, not an OEM or authorised distributor of any of the brands listed. Final model availability, lead-time and price are confirmed at the time of quotation. Specifications should be cross-checked against the manufacturer's official datasheet before placing the order.

Send Us Your Motor List

Motor kW and count, starting method, enclosure environment, and any drawing you have. We'll come back with a panel proposal — and the geared drives to match if you need them.

Request a Quote Call +91 9820383719